Speaker
Mr
Jochen Munz
(Lechler GmbH)
Description
The paper describes the converting to a new generation of descaling nozzles in a conventional hot strip mill for steel. There are descaling stations behind the reheating furnace, on the roughing mill stands and in front of the finishing mill. Before the converting, there had been three high pressure pumps in operation to supply the descaling stations. The new descaling nozzles had been tested first in the finishing mill descaler with good results. There were considerable water savings without compromising the descaling effect and the material surface quality. After a successful test, the remaining descaling stations had been converted accordingly. The overall water savings was approx. 20%, which allowed shutting off one of the three high-pressure pumps. Electrical energy saving amounts to 9,300,000* kWh/ year. At the current energy costs this is equivalent to 2,100,000 TL / 635,000 EUR**. Additional advantages are seen such as reduced material cooling and the lower wear of the components of the whole high-pressure water hydraulic system.
Author
Mr
Hubertus Wenig
(Lechler GmbH)
Co-authors
Mr
Abdullah Savascioglu
(Metalform A.S.)
Mr
Bilal Akgül
(Colakoglu Metalurji A.S.)
Mr
Jochen Munz
(Lechler GmbH)
Mr
Jürgen Frick
(Lechler GmbH)